CLASSIC - BUG LIST as of FW2096
Last Updated 3 years ago

FIRMWARE BUGS THAT NEED SQUASHING:

BUG#1-Setting FLOAT voltage down to 10V, pressing the DOWN ARROW again sets it to 9.9V, move cursor to see.
BUG#2-Same thing for LIMITS, BATTERY AMPS, setting to 5.0A and moving the cursor shows 4.0A (Classic limits to 4.0 btw)
BUG#3-While navigating the menus under CHARGE, the cursor can be moved to the CLASSIC'S NAME for no good reason.
BUG#4-Aux2 LOGIC INPUT-2 Needs the PULL UP BIT set to put a HIGH on it.
BUG#5-Setting ABSORB time to ZERO rolls over to 18:03 when you hit "03"
BUG#6-TIME SYNC does not SAVE unless you move off it and press ENTER.
BUG#7-MNGP MAC address issue. 60:1D:0F:00:53:3E shows as 60:1D:FF:FF:XX:XX. Just replace FF:FF with 0F:00 for MM

QUIRK#1-DISABLE T-COMP for other battery types also disables HI BATT Limit setting. NiFe & Lithium don't use T-COMP but sure can use HI BATTERY SHUTDOWN
QUIRK#2-

FIRMWARE ISSUES:
ISSUE#1-Random EQ when using the F-Me networking.
ISSUE#2-Using an MNGP with FW2054 on earlier Classic FW hoses the Classic when you VMM needing a JP-1/BOOT to fix.
ISSUE#3-NETWORK, Classic is sending a FIN ("No more data from sender") packet at the start.
ISSUE#4-LOCAL AP,  port number on the computer running the Local Application is incremented each time. Will crash sooner or later.
ISSUE#5-Time in float maxes at 18: and change because the register is full.
ISSUE#6-

Feature requests:
FEATURES#1-AUX 1 for BATTERY TEMP setting ON/OFF RELAY or 12V based on setting. HOLD & DELAY needed.