Frequently Asked Question

CLASSIC - ENDAMPS - Setup for more than one Classic
Last Updated 6 years ago

Using ENDAMPS with a multi-Classic setup requires a few unique settings.

1) A SHUNT and properly working Whizbang JR is required.
2) ALL other Classics need to have ENDAMPS set to 0.0 (Not used)
3) ABSORB times need to be properly SET.
4) Follow-Me needs to be setup and working.

The Classic with the Whizbang JR is the one that is going to control ENDAMPS. (MASTER)
Be sure ENDAMPS is set to use the SHUNT and not the CLASSIC.
The ABSORB time for all Classics needs to be set 30 minutes longer than normal.
The SLAVES get set an additional 10 minutes over this.

ENDAMPS will only trigger while in the ABSORB Mode.  Any Classic in BULK or FLOAT will be soon setting all the rest to BULK or FLOAT if the Follow-Me network is working.